Rebuilding Ampico "A" Secondary Valves
By Joel Cluskey

Mount an old flatiron upside down (with a clamp).  Set the
valves upside down on the hot face of the iron for about a minute.
Pick them up and pull the metal seat out with a pin nose pliers.
Safe and clean.

Joel Cluskey
Pittsburgh, Pennsylvania