MMD > Archives > July 2013 > 2013.07.06 > 03Prev  Next


Air Pressure Stiffeners In Coinola Box Pump
By Tony Marsico

[ Scotty Greene wrote in 130705 MMDigest:

> ... can I get away with adding external stiffeners, or do I have
> to remove the motor cloth and put the stiffeners inside, as they
> are on a pressure pump?

Scotty,  the correct thing to do is to put stiffeners in the pump.
I don't see them very often on the outside of the pump.

Look at the valves and also the seal around the crankshaft coming
out of the pump.  Make sure that is tight and your volume [air flow]
should come up on the pump.

Tony Marsico - Bayernhof Museum
Pittsburgh, Pennsylvania


(Message sent Sat 6 Jul 2013, 17:58:42 GMT, from time zone GMT-0400.)

Key Words in Subject:  Air, Box, Coinola, Pressure, Pump, Stiffeners
Enter text below to search the MMD Website with Google