MMD > Archives > November 2016 > 2016.11.11 > 10Prev  Next


Band Organ Blower Specifications
By John Haskey

Dave Vincent asks about blower sizing [161108 MMDigest].  Organ Supply
Industries has guidelines for blower sizing for pipe organs in Chapter
8 of their catalog, available for download here:

http://www.organsupply.com/assets/CatalogPDFs/2014/Books-Misc.-Revision.pdf 

I'm not sure if this would translate well to a band organ but their
rule of thumb is 68 cubic feet per minute [cfm] for a rank of 61 pipes
at 7" water column pressure.  If your 200 pipes was approximately 3.5
ranks that would be about 240 cfm.

John Haskey


(Message sent Fri 11 Nov 2016, 05:05:01 GMT, from time zone GMT-0800.)